CLASSIFICATION
Category
Return
National Service Hotline:
0574-87762771
Product details
Excellent and reliable performance:
• With partial load operation function, it can effectively reduce power consumption and save energy
Low noise design, suitable for high standard building requirements
Before leaving the factory, conduct a complete machine operation test to ensure the safe and reliable performance of the unit
Can still operate normally at an ambient temperature of 43 ℃
Specialized electrical control boxes and color coded wiring further simplify installation. At the time of leaving the factory, a water filter is attached to the body and installed on-site by the customer to prevent blockage of the water side heat exchanger. The detachable panel facilitates the installation, debugging, and maintenance of the unit
The whole machine has a compact structure, a low body height, and can be installed 1m away from the wall. The exterior design is perfectly matched with the building
The water flow protection system is a standard configuration of the unit, so there is no need to install a water flow switch on site
The unit provides dry contacts to control the chilled water pump
Powerful control functions:
Reset the temperature of the chilled water
• Soft loading function of the unit
• Compressor wheel sequence control
• Call auto start function
Practical external controls:
• Terminal interlocking
• Basic load control function
Mode switching and alarm output
Flexible and easy operation and maintenance:
• Full Chinese menu
• Self diagnosis
• Water pump cleaning function
• Manual defrosting
Comprehensive protective measures
• Anti freezing protection
• Compressor operation protection
• Water outlet temperature protection
• Power on delay protection
Motor overload protection
• Water side panel battery swapping and heating protection
• With partial load operation function, it can effectively reduce power consumption and save energy
Low noise design, suitable for high standard building requirements
Before leaving the factory, conduct a complete machine operation test to ensure the safe and reliable performance of the unit
Can still operate normally at an ambient temperature of 43 ℃
Specialized electrical control boxes and color coded wiring further simplify installation. At the time of leaving the factory, a water filter is attached to the body and installed on-site by the customer to prevent blockage of the water side heat exchanger. The detachable panel facilitates the installation, debugging, and maintenance of the unit
The whole machine has a compact structure, a low body height, and can be installed 1m away from the wall. The exterior design is perfectly matched with the building
The water flow protection system is a standard configuration of the unit, so there is no need to install a water flow switch on site
The unit provides dry contacts to control the chilled water pump
Powerful control functions:
Reset the temperature of the chilled water
• Soft loading function of the unit
• Compressor wheel sequence control
• Call auto start function
Practical external controls:
• Terminal interlocking
• Basic load control function
Mode switching and alarm output
Flexible and easy operation and maintenance:
• Full Chinese menu
• Self diagnosis
• Water pump cleaning function
• Manual defrosting
Comprehensive protective measures
• Anti freezing protection
• Compressor operation protection
• Water outlet temperature protection
• Power on delay protection
Motor overload protection
• Water side panel battery swapping and heating protection
Next